Description
K-10,12,15 inch Patient Monitor
10,12,15 inch high resolution touch screen with multiple display modes
Standard Parameters: 3/5 lead ECG, RESP, SpO2, PR, NIBP, TEMP
Optional Parameters: 4-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cardiac Output, Cerebral State Monitoring
28 types of arrhythmia and S-T segment analysis
2 year warranty on main unit and half year warranty on accessories
K-10,12,15 inch Patient Monitor
K-10,12,15 Features
• 10”, 12” 15″ high-resolution display Touch screen optional
• 9 traces on-screen waveforms and maximal up to 13
• User customized NIBP measuring cycles up to 5-phase
• Data export and software upgrade
• Versatile clinical calculations for application convenience
• HL7 protocol, Bed to bed view and 5-lead ECG available
Technical Specifications |
ECG Input dynamic range: ±(0.5~5 mVp) Differential input impedance: =10 MO Bandwidth: 0.05~150 Hz (Diagnostic), 0.5~40 Hz (Monitoring), 1~20 Hz (Operation) CMRR: =90 dB (Diagnostic) / =105 dB (Monitoring & Operation) Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater Pacemaker pulse detection and rejection functionRESP Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greaterTEMP Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °CNIBP Technique: Oscillometric method Typical measurement time: <30 seconds (adult cuff) NIBP measuring range: SYS: 40~275 mmHg (Adult) / 40~200 mmHg (Pediatric) / 40~135 mmHg (Neonate) NIBP measuring range: DIA: 10~210 mmHg (Adult) / 10~150 mmHg (Pediatric) / 10~95 mmHg (Neonate) NIBP measuring range: MAP: 20~230 mmHg (Adult) / 20~165 mmHg (Pediatric) / 20~110 mmHg (Neonate) NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode NIBP measuring accuracy: Mean difference: ±5 mmHg Standard deviation: 8 mmHg Auto measuring intervals: 1-480 minSpO2 Technique: Dual-wavelength optical method Measuring range: 0%~100% ±2% for SpO2 range 70~100% PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greaterLow perfusion performance: As low as 0.3%.Other Specifications Power supply: AC 100-240 V, 50/60 Hz, 60 VA Built-in lithium battery: 11.1V/4400 mAh Display: 12 or 15 inch TFT display Alarming method: 3 levels audible-visible alarm Networking: Ethernet Safety standard: IEC 60601-1 |
Standard accessories |
– Adult SpO2 probe – NIBP adult cuff – SpO2 extension cable – ECG cable – Skin temperature probe – Power supply cable – Re-chargeable lithium battery – Dust-protective cover – Disposable electrode – Manual: GB, FR, IT, ES. – PC software: GB, IT, ES. |
Application overview
- Suitable for use in hospitals and clinics
Reviews
There are no reviews yet.